The variable High-Voltage Power Supply 0-3kV
You’ll need a variable high-voltage supply to operate the detector.
The transformer is uncritical and easy to build. Use a E or EI core without air gap with an AL value of approx. 2000nH/W2. The primary coil has 25 windings of 0.7 - 1 mm magnet wire; the secondary coil has 500 windings of 0.2 - 0.3 mm magnet wire. Make sure that the insulation of the primary and secondary coil is well done. You should only use a plastic bobbin (Wickelkern in german) with 2 chambers - one for the primary coil the second chamber for the secondary coil.
Related Links
More circuit about Power supply
More circuit about switching power supply
More circuit about High voltage power supply
0-1000V Regulated High Voltage Power Supply
High Voltage Generator for Low Current Applications By 4069
More circuit by IC 4011
Read More Source:
http://www.cosmicrays.org/muon-power-supply.php#captain
Thank you.